What EPS high tower central vacuum cooling system high does?
• Central vacuum supply: Replaces small, separate vacuum pumps on every molding machine with one large, centralized vacuum station.
• Vacuum cooling: Pulls a strong vacuum to rapidly cool & dry EPS molds after steam heating.
• Water recovery & cooling: Condenses water vapor and cools the circulating water in a tall tower structure.
Key design of EPS high tower central vacuum cooling system high
• Vertical tall structure (typically 10–14m high)
• Large vacuum tanks + cooling tower in one vertical frame
• Waterfall / water-curtain heat exchange inside the tower
• Multi-stage vacuum pumps (liquid-ring type) at the base
• PLC automatic control
How EPS high tower central vacuum cooling system high works?
1. The tower maintains a stable high vacuum reserve.
2. When EPS molds finish steaming, they quickly draw vacuum from the central system.
3. Hot vapor is sucked into the tower, sprayed with cooling water, condensed, and separated.
4. Vacuum pumps handle only dry(er) air/gas → higher efficiency, less wear.
Technical data of EPS high tower central vacuum cooling system high
|
Item |
Unit |
HS-TSZK-200 |
HS-TSZK-300 |
HS-TSZK-400 |
HS-TSZK-500 |
|
Sucking rate |
M3/h |
800 |
120 |
1600 |
2000 |
|
Power |
Kw |
11*2 |
11*3 |
11*4 |
11*5 |
|
Shape Machine QTY |
Sets |
6~8 |
10~15 |
15~20 |
20~25 |
TAG:
EPS high tower central vacuum cooling system
EPS high tower central vacuum cooling system
Category:
Get A Quote
We will contact you within one working day. Please pay attention to your email.